sesion4 recasens01This article presents the highlights of a study carried out in order to determine the odour impact of a Street Cleaning Station located in the city and surrounded by apartments. Therefore, it shows the selection process of the metholodgy that meets the best the goals of the study, the physical and operational characteristics of the plant, the time available and the Budget.

The results of this study show the need of customising the methodology to each Project, taking into account all the issues that can contribute to odour impact generation. Thanks to this project, the company could convince its neighbours and the Administration that no impact was generated, so the presence of the plant was compatible with the apartments in the building.

 

 

 

  • Find this article in other languages:
  1. Deutsch
  2. Français
  3. Español
  4. Polski
  5. اللغة العربية

   

There is no translation available.

In Chile odour issues are becoming critical. The community is putting pressure on authorities and industry is being forced to take actions in order to minimize odour nuisances. There are approaches that allow delivering "reliable" results<

E. Contreras y V. Zorich M.

Ecometrika, Américo Vespucio 2296, Conchalí, Santiago, Chile. www.ecometrika.com, econtreras@ecometrika.cl, vzorich@ecometrika.cl.

Keywords: Belgian plume method, odour exposure impact assessment, odour control master plan.

contreras imagen engAbstract

In Chile odour issues are becoming critical. The community is putting pressure on authorities and industry is being forced to take actions in order to minimize odour nuisances. There are approaches that allow delivering "reliable" results such as odour dispersion modelling, yet the question remains on how reliable the result of modelling can be. Are the results of modelling a true representation of the real odour impact and –most importantly– nuisances? In order to check the results obtained from a dispersion model, and validate how representative they are, it is essential and necessary to verify these. In this paper two case studies are presented that illustrate how methodologies by panel field can validate parallel modelling approaches. In both case, validation process was a valuable tool for detecting errors and obtaining reliable results. We conclude that modelling results must be validated by another methodology or they can be clearly misleading.

 

 

 

 

  • Find this article in other languages:
  1. Deutsch
  2. French
  3. Español
  4. Polski
  5. اللغة العربية

 

 

If you find this article interesting, you might be also interested in these articles.

 

There is no translation available.

O-nose8    The market of olfactometers is rapidly growing and changing. As we saw in December, a new portable olfactometer named Scentroid SC302 came out and fresh from the bakery. That was a little and nice surprise for all of us and a shot for the olfactometer market dominated at this time by the German makers of the ECOMA TO8. This time, and just a few months after the show up of the Scentroid SC302, we have a new piece of engineering coming to the stage: The Onose-8 ® dynamic dilution olfactometer.

   The Onose-8 ® dynamic dilution olfactometer is the result of many years of research and development by the engineers and scientists from a consulting firm based in Quebec. The Onose-8 ® olfactometer is designed according with the following standards:

  • ASTM 679
  • EN 13725
  • VDI 3881 and 3882