There is no translation available.

sesion4 recasens01This article presents the highlights of a study carried out in order to determine the odour impact of a Street Cleaning Station located in the city and surrounded by apartments. Therefore, it shows the selection process of the metholodgy that meets the best the goals of the study, the physical and operational characteristics of the plant, the time available and the Budget.

The results of this study show the need of customising the methodology to each Project, taking into account all the issues that can contribute to odour impact generation. Thanks to this project, the company could convince its neighbours and the Administration that no impact was generated, so the presence of the plant was compatible with the apartments in the building.

 

 

 

  • Find this article in other languages:
  1. Deutsch
  2. Français
  3. Español
  4. Polski
  5. اللغة العربية

   

There is no translation available.

 Many Environmental Treatment and Valorisation Plants (ITVAs), as wastewater treatment plants, composting plants, biomethanisation plants,... and other often generate odoriferous emissions which if not treated

S. Nadal1, *, M. Latorre1 y A. Bomboí1
1 Sistemas y Tecnologías Ambientales S.A. * Silvia Nadal: snadal@sta-at.com

Keywords: Advanced Biological Filters, Biofiltration, Thermal Oxidation, Non Thermal Plasma, Supplementary Pneumatical Propulsion

 sesion4 nadal02Abstract

   Many Environmental Treatment and Valorisation Plants (ITVAs), as wastewater treatment plants, composting plants, biomethanisation plants,... and other often generate odoriferous emissions which if not treated properly can actually cause serious nuisance to neighbors.

There is no translation available.

Different alternatives exist for the removal of odours and other volatile compounds from waste gases. On one side, non-biological processes can be used (mainly absorption, adsorption, and oxidation processes)

C. Kennes, H.N. Abubackar y M.C. Veiga
 La Coruña (UDC) University, Campus da Zapateira – Ingeniería Química, Rua da Fraga 10, E – 15008 – La Coruña, España. Tel.: 34-981-167000; Fax.: 34-981-167065; Kennes_at_ udc.es

Keywords: Bioreactor, biofilter, bioscrubber, trickling filter, odours, air diffusion bioreactor.